| DIMENSION | AS DETAILED | AS FIT-UP TOLERANCE | NOTES |
|---|---|---|---|
| Groove Angle (α) | 60° | +10°, −5° | — |
| Root Opening (R) | 1/8 to 3/16 in | +1/16 in, −0 | Tack inside or use bridge tacks |
| Root Face (f) | 1/16 to 1/8 in | +1/16 in, −0 | — |
| Pipe Diameter | ≥ 4 in OD | — | D1.1 Clause 5 — prequalified ≥4 in |
| Size | Class | Amps | Volts | Position Limit | Notes |
|---|---|---|---|---|---|
| 3/32 in | E6010 | 40-80 | 18-22 | All | ROOT PASS ONLY — SMAW DCEP |
| 1/8 in | E6010 | 75-130 | 19-24 | All | ROOT PASS ONLY — SMAW DCEP |
| 0.035 in | E71T-1C | 130-210 | 24-28 | All | Hot Pass/Fill/Cap — FCAW-G |
| 0.045 in | E71T-1C | 150-300 | 24-30 | All | Hot Pass/Fill/Cap — FCAW-G |
| Pass | Process | Filler / Class | Size | Current | Amps | Volts | Speed | Technique |
|---|---|---|---|---|---|---|---|---|
| Root | SMAW | E6010 | 3/32 in | DCEP | 40-80 | 18-22 | 3-7 in/min | either / uphill |
| Root | SMAW | E6010 | 1/8 in | DCEP | 75-130 | 19-24 | 4-8 in/min | either / uphill |
| Hot Pass | FCAW-G | E71T-1C | 0.035 in | DCEP | 130-210 | 24-28 | 8-16 in/min | either / uphill |
| Hot Pass | FCAW-G | E71T-1C | 0.045 in | DCEP | 150-300 | 24-30 | 8-16 in/min | either / uphill |
| Fill | FCAW-G | E71T-1C | 0.035 in | DCEP | 130-210 | 24-28 | 8-16 in/min | either / uphill |
| Fill | FCAW-G | E71T-1C | 0.045 in | DCEP | 150-300 | 24-30 | 8-16 in/min | either / uphill |
| Cap | FCAW-G | E71T-1C | 0.035 in | DCEP | 130-210 | 24-28 | 8-16 in/min | either / uphill |
| Cap | FCAW-G | E71T-1C | 0.045 in | DCEP | 150-300 | 24-30 | 8-16 in/min | either / uphill |
| VARIABLE | TOLERANCE | NOTES |
|---|---|---|
| Amperage (Current) | ± 10% | From values specified on WPS |
| Voltage | ± 15% | From values specified on WPS |
| Travel Speed | ± 25% | From values specified on WPS |
| Wire Feed Speed | ± 10% | GMAW, FCAW, SAW only |
| DIMENSION | AS DETAILED | AS FIT-UP TOLERANCE | NOTES |
|---|---|---|---|
| Groove Angle (α) | 60° | +10°, −5° | — |
| Root Opening (R) | 1/8 to 3/16 in | +1/16 in, −0 | Tack inside or use bridge tacks |
| Root Face (f) | 1/16 to 1/8 in | +1/16 in, −0 | — |
| Pipe Diameter | ≥ 4 in OD | — | D1.1 Clause 5 — prequalified ≥4 in |
| Size | Class | Amps | Volts | Position Limit | Notes |
|---|---|---|---|---|---|
| 3/32 in | E6010 | 40-80 | 18-22 | All | ROOT PASS ONLY — SMAW DCEP |
| 1/8 in | E6010 | 75-130 | 19-24 | All | ROOT PASS ONLY — SMAW DCEP |
| 0.035 in | E71T-1C | 130-210 | 24-28 | All | Hot Pass/Fill/Cap — FCAW-G |
| 0.045 in | E71T-1C | 150-300 | 24-30 | All | Hot Pass/Fill/Cap — FCAW-G |
| Pass | Process | Filler / Class | Size | Current | Amps | Volts | Speed | Technique |
|---|---|---|---|---|---|---|---|---|
| Root | SMAW | E6010 | 3/32 in | DCEP | 40-80 | 18-22 | 3-7 in/min | either / uphill |
| Root | SMAW | E6010 | 1/8 in | DCEP | 75-130 | 19-24 | 4-8 in/min | either / uphill |
| Hot Pass | FCAW-G | E71T-1C | 0.035 in | DCEP | 130-210 | 24-28 | 8-16 in/min | either / uphill |
| Hot Pass | FCAW-G | E71T-1C | 0.045 in | DCEP | 150-300 | 24-30 | 8-16 in/min | either / uphill |
| Fill | FCAW-G | E71T-1C | 0.035 in | DCEP | 130-210 | 24-28 | 8-16 in/min | either / uphill |
| Fill | FCAW-G | E71T-1C | 0.045 in | DCEP | 150-300 | 24-30 | 8-16 in/min | either / uphill |
| Cap | FCAW-G | E71T-1C | 0.035 in | DCEP | 130-210 | 24-28 | 8-16 in/min | either / uphill |
| Cap | FCAW-G | E71T-1C | 0.045 in | DCEP | 150-300 | 24-30 | 8-16 in/min | either / uphill |
| VARIABLE | TOLERANCE | NOTES |
|---|---|---|
| Amperage (Current) | ± 10% | From values specified on WPS |
| Voltage | ± 15% | From values specified on WPS |
| Travel Speed | ± 25% | From values specified on WPS |
| Wire Feed Speed | ± 10% | GMAW, FCAW, SAW only |